DS Series Encoder/Decoder Specifications
Parameter Symbol Min. Typ. Max. Units Notes
Operating Voltage V
CC
2.2 5.5 VDC
Encoder Supply Current l
CCENC
At 2.2V 200 µA 1
At 3.3V 250 µA 1
At 5.0V 400 µA 1
Decoder Supply Current l
CCDEC
At 2.2V 300 µA 1
At 3.3V 400 µA 1
At 5.0V 675 µA 1
Power-Down Current l
PDN
At 2.2V 0.3 µA
At 3.3V 0.3 µA
At 5.0V 0.4 µA
Input Low V
IL
0.0 0.2 * V
CC
V 2
Input High V
IH
0.8 * V
CC
V
CC
V 3
Output Low V
OL
0.0 0.6 V
Output High V
OH
V
CC
-0.7 V
CC
V
Input Sink Current 25 mA 4
Output Drive Current 25 mA 4
Operating Temp. Range −40 +85 ºC
Response Time
Holtek Protocol 135 ms
Serial Protocol 40 ms
Electrical SpecicationsOrdering Information
Ordering Information
Part Number Description
LICAL-EDC-DS001 DS Series Encoder/Decoder
EVAL-xxx-DS DS Series Evaluation Kit
Encoder/Decoders are supplied in tubes of 18 pcs.
Figure 2: Ordering Information
Figure 4: Electrical Specifications
1. Current consumption with no active loads.
2. For 3V supply, (0.15 x 3.0) = 0.45V max.
3. For 3V supply, (0.8 x 3.0) = 2.4V min.
4. Total current = 300mA
Absolute Maximum Ratings
Figure 3: Absolute Maximum Ratings
Absolute Maximum Ratings
Supply Voltage V
CC
−0.3 to +6.5 VDC
Any Input or Output Pin −0.3 to V
CC
+ 0.3 VDC
Max. Current Sourced By Output Pins 25 mA
Max. Current Sunk By Output Pins 25 mA
Max. Current Into V
CC
250 mA
Max. Current Out Of GND 300 mA
Operating Temperature −40 to +85 ºC
Storage Temperature −65 to +150 ºC
Exceeding any of the limits of this section may lead to permanent damage to the device.
Furthermore, extended operation at these maximum ratings may reduce the life of this
device.
Warning: This product incorporates numerous static-sensitive
components. Always wear an ESD wrist strap and observe proper ESD
handling procedures when working with this device. Failure to observe
this precaution may result in module damage or failure.